窗台施工工艺节选.doc
一、窗台新的施工工艺
窗台渗漏的原因:
(1) 窗台顶面外侧部分坡度不够,出现倒泛水;
(2) 窗台抹灰不平,没有向外的坡度;
(3) 窗框与抹灰面接触处,填塞不实、封闭不严或密封胶开裂。
新的施工措施:
1、 在贴外墙面砖时,按照窗台的控制标高留置窗台面,并将窗台顶面面砖按30~40的坡度粘贴。
2、 窗洞口抹灰时,在窗框处,沿窗台顶面面砖里边沿,用水泥砂浆做一高20~30mm的台阶,并且窗框下面的抹灰向外略微倾斜(框是弹性安装,四周要留5~8mm的空隙,抹灰面略微放坡,不影响窗框安装)。
3、 在窗框安装好后,岩棉或巴提玛枪式聚氨酯泡沫填缝剂填塞密实,在窗框两侧缝隙用硅酮密封胶密封即可。
通过采用上述方法,消除了窗台倒泛水现象,解决了窗台渗漏的问题,效果良好。
二、防止地面砖空鼓的措施
1、 基层必须认真清扫干净,并洒水充分湿润,湿润时间一般为24h,且无积水现象,以保证垫层与基层结合良好。
First, new construction technology in window
Window leakage of reasons:
(1) the lateral part of the slope of the top window is not enough, there inverted pan of water;
(2) uneven plaster window, there is no outward slope;
(3) The window frames and plaster surface contact, filling false, strictly closed or sealed plastic cracking.
Construction of new measures:
1, when facing tiles in the paste, according to the control window sill surface elevation of lien, and the top tile window by 30 to 40 of the slope paste.
2, when the window hole plaster, in the window frames Department, along the windowsill inside the top edge of tile, cement mortar to make a high-level 20 ~ 30mm, and the window frame plaster below tilt slightly outward (box is a flexible installation, to stay around 5 ~ 8mm gap, floated slightly sloping, does not affect the window frame installation).
3, the window frames installed, rock wool or polyurethane foam sealant gun-type Ba Tima dense packing in window frames on both sides of gaps can be sealed with silicone sealant.
By using this method to eliminate the phenomenon of window flashing back to solve the window leakage problem, good results.
Second, measures to prevent land Facing Tiles
1, grass-roots must be carefully cleaned, and the full wet sprinkler, wet time usually 24h, and no water phenomenon in order to ensure a good combination of cushion and grass-roots.